Lubricant Lab


*Click the button for see table

Individual Oil Property Parameter

Individual Oil Test Parameter
No. Parameter Unit Method Price Other link
1 Ash Content %wt ASTM D 482-03 Learn more
2 API Gravity ASTM D 1298-99 Learn more
3 Aromatic Content %vol Gas Chromatography Learn more
4 Blotter Spot Test (Qualitative) Learn more
6 Calorific Value (Gross-Nett / HHV-LHV) kJ/kg ASTM D 240-97 Learn more
7 Cetane Index ASTM D 4737-03 Learn more
8 Cetane Number ? Learn more
9 Chlorine Content SPECTROSCOPY Learn more
10 Color ASTM 1500-98 Learn more
11 Conradson Carbon Residue (CCR) %wt ASTM D 189-97 Learn more
12 Copper Strip Corrosion ASTM D 130-04 Learn more
13 Density kg/L ASTM D 1298-04 Learn more
14 Distillation %vol ASTM D 86-04 Learn more
15 Doctor Test (Qualitative) positive/ negative ASTM D 4952-02 Learn more
16 Drainage Time 50% Foam hours, minutes ? Learn more
17 Dropping Point °C ASTM D 566-02 Learn more
18 Dropping Point for overwide temperature Range °C ASTM D 2265-00 Learn more
19 Dynamic (Absolute) Viscosity at 40 °C cP ASTM D 445-04(mod) Learn more
20 Dynamic (Absolute) Viscosity at 100 °C cP ASTM D 445-04(mod) Learn more
21 Equilibrium Reflux Boiling Point (ERBP) °C SNI 06 – 2769 – 92 Learn more
22 Expansion Volume (Foam) times ? Learn more
23 Flash Point COC °C ASTM D 92-00 Learn more
24 Flash Point PMCC °C ASTM D 93-00 Learn more
25 Foaming Characteristics seq1/seq2/seq3 ASTM D 892-98 Learn more
26 Foaming Test (High Temp – Seq 4) Tend/Stbl ASTM D 892-98 Learn more
27 FTIR Fingger Print ASTM E 2412 – 04 Learn more
28 FTIR (Oxidation, Nitration, Sulfation, Water and Fuel Dilution) Abs ASTM E 2412 – 04 Learn more
29 Fuel Dilution %wt ASTM D 322-97 Learn more
30 Initial Boiling Point (IBP) °C ASTM D 86-04 Learn more
31 Iodine Value AOCS Cd 1-25 Learn more
32 Kinematic Viscosity at 40 °C cSt ASTM D 445-04 Learn more
33 Kinematic Viscosity at 100 °C cSt ASTM D 445-04 Learn more
34 Lead Content (Pb) on Fuel ppm (mg/kg) ASTM D 3237-02 Learn more
35 Metal Individual Analysis (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si, Mg, Zn, Ca) on Lube Oil ppm (mg/kg) ASTM D 5185 – 09 Learn more
36 Metal Additives Analysis (Ca, Mg, Zn) on Lube Oil ppm (mg/kg) ASTM D 4628-02 Learn more
37 Metal Wear Analysis (Fe, Cu, Cr, Al, Pb, Ni, Sn, Na, Si) on Lube ppm (mg/kg) ASTM D 5185 – 09 Learn more
38 Mercaptane Sulfur (Qualitative) positive/ negative IP 30 Learn more
39 Napthanic Content %vol Gas Chromatography Learn more
40 Olefin Content %vol Gas Chromatography Learn more
42 Parafinic Content %vol Gas Chromatography Learn more
43 Particulate Contaminant mg/100 mL ASTM D 2276-00 Learn more
44 Pentane Insoluble Content %wt ASTM D 893-02 Learn more
45 pH pH Meter ( SNI 06 – 2769 – 92 ) Learn more
46 Pour Point °C ASTM D 97-04 Learn more
47 Research Octane Number (RON) ? Learn more
48 Saponification Value ASTM D 94-00 Learn more
49 Sediment %wt ASTM D 473-02 Learn more
50 Smoke Point °C IP 57/55 (86) Learn more
51 Specific Gravity (SG) ASTM D 1298-99 Learn more
52 Sulfated Ash %wt ASTM D 874-00 Learn more
53 TAN / SAN mg KOH/g ASTM D 974-97 Learn more
54 TBN mg KOH/g ASTM D 2896-98 Learn more
55 Toluene Insoluble Content %wt ASTM D 893-02 Learn more
56 Total Insoluble %wt ASTM D 893-02 Learn more
57 Viscosity Index ASTM D 2270-98 Learn more
58 Water Content-Crackle Test (Qualitative) positive/ negative Learn more
59 Water Content by Distillation %wt ASTM D 95-99 Learn more
60 Water and Sediment %vol ASTM D 1796-00 Learn more
61 Water Separation Characteristic (ml) Oil-Water-Eml ASTM D1401-98 Learn more
62 Wet – ERBP °C SNI 06-2769-92 Learn more

 

Base Oil Anlysis

General Base Oil Analysis – Package A
No. Parameter Unit Method
1 Base Oil Color Index ASTM D1500
2 Kinematic Viscosity @ 40 C and 100 C cSt ASTM D445
3 Viscosity Index (VI) Index ASTM D2270
4 Flash Point PMCC C ASTM D93
5 Fluid Density kg/L ASTM D1298
6 Solubility by Viscosity Gravity Constant (VGC) Index ASTM D2501
7 Copper Strip Corrosion Index ASTM D130
8 Demulsibility Characteristic (30 minutes) mL ASTM D1401
9 Water Content by KF ppm ASTM D6304
10 Sulphur Content ppm ASTM D 4294,
ASTM 2622,
ASTM D5185-13e1
11 Neutralization Number mg KOH/g ASTM D974

Regular Used Oil Anlysis

1. Regular Package Test for In-Service Oil of Engine
Package Code: REG-INDUS-ROT
Minimum liter of sample required for each sample: 150 mL
Lead Time: 3 days
Usually Applied for: Analyzing Lubricating Oil condition of various type of Plant rotating equipment (Pump, Blower, Fan, Air Compressor, Turbine, etc)
Price Per-sample: Contact Us
Recommended Sampling Frequency: every 1 – 3 months
No. Parameter Unit Method Other link
1 Color ASTM D 1500 Learn more
2 Kinematic Viscosity at 100 °C cSt ASTM D 445 – 97 Learn more
3 Total Base Number (TBN) mg KOH/g ASTM D 2896 – 98 Learn more
4 “Metal Content:Wear Metal (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si) and Metal Additive (Ca, Mg, Zn, P)” ppm ASTM D 5185 – 09 Learn more
5 FTIR (Oxidation, Nitration, Water) Abs ASTM E 2412 – 04 Learn more
2. Regular Package Test for In-Service Oil of NON-Engine (Mining)
Package Code: REG-USED-NONEGN
Minimum liter of sample required for each sample: 150 mL
Lead Time: 3 days
Usually Applied for: Analyzing Non-engine oil condition, which are for Heavy Duty Mining Equipment.
Price Per-sample: Contact Us
Recommended Sampling Frequency: every 500 – 1000 hours
No. Parameter Unit Method Other link
1 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 learn more
2 Total Acid Number (TAN) mg KOH/g ASTM D 2896 – 98 learn more
3 “Metal Content:Wear Metal (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si) and Metal Additive (Ca, Mg, Zn, P)” ASTM D 5185 – 09 learn more ppm
4 FTIR (Oxidation, Nitration, Water) Abs ASTM E 2412 – 04 learn more
3. Regular Package Test for In-Service Oil of Various Plant Rotating Equipment
Package Code: REG-INDUS-ROT
Minimum liter of sample required for each sample: 150 mL
Lead Time: 3 days
Usually Applied for: Analyzing Lubricating Oil condition of various type of Plant rotating equipment (Pump, Blower, Fan, Air Compressor, Turbine, etc)
Price Per-sample: Contact Us
Recommended Sampling Frequency: every 1 – 3 months
No. Parameter Unit Method Other link
1 Color ASTM D 1500 learn more
2 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 learn more
3 Total Acid Number (TAN) mg KOH/g ASTM D 2896 – 98 learn more
4 “Metal Content:Wear Metal (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si) and Metal Additive (Ca, Mg, Zn, P)” ASTM D 5185 – 09 ppm learn more
5 FTIR (Oxidation, Nitration, Water) Abs ASTM E 2412 – 04 learn more
4. Regular Package Test for In-Service Oil of Hydrocarbon Gas Compressor and Refrigeration Compressor
Package Code: REG-INDUS-HCGAS
Minimum liter of sample required for each sample: 150 mL
Lead Time: 3 days
Usually Applied for: Analyzing Lubricating Oil condition of Hydrocarbon Gas and Refrigeration Compressor
Price Per-sample: Contact Us
Recommended Sampling Frequency: every 1 – 3 months
No. Parameter Unit Method Other link
1 Color ASTM D 1500 learn more
2 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 learn more
3 Total Acid Number (TAN) mg KOH/g ASTM D 2896 – 98 learn more
4 “Metal Content:Wear Metal (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si) and Metal Additive (Ca, Mg, Zn, P)” ppm ASTM D 5185 – 09 learn more
5 FTIR (Oxidation, Nitration, Water) Abs ASTM E 2412 – 04 learn more
6 Flash Point – COC °C ASTM D 92 learn more
5. Regular Package Test for In-Service Oil of Steam and Gas Turbine
Package Code: REG-INDUS-TURBINE
Minimum liter of sample required for each sample: 150 mL
Lead Time: 3 days
Usually Applied for: Analyzing Lubricating Oil condition of Hydrocarbon Gas and Refrigeration Compressor
Price Per-sample: Contact Us
Recommended Sampling Frequency: every 1 – 3 months
No. Parameter Unit Method Other link
1 Color ASTM D 1500 learn more
2 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 learn more
3 Total Acid Number (TAN) mg KOH/g ASTM D 2896 – 98 learn more
4 “Metal Content:Wear Metal (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si) and Metal Additive (Ca, Mg, Zn, P)” ppm ASTM D 5185 – 09 learn more
5 Water content By Karl Fischer ppm (mg/kg) ASTM E 6304-04 learn more
6 Flash Point – COC °C ASTM D 92 learn more
7 MPC (Varnish Potential) Test rating MPC learn more

 

Advanced Used Oil Analysis

1. Advanced Package Test for In-Service Oil of Industrial Hydraulic Equipment
Package Code: ADV-INDUS-HYD
Minimum liter of sample required for each sample: 1000 mL
Lead Time: 3 days
Usually Applied for: Analyzing Lubricating Oil condition of various type industrial hydraulic equipment
Price Per-sample: Contact us
Recommended Sampling Frequency: Every 1 – 3 months
No. Parameter Unit Method Other link
1 Color ASTM D 1500 learn more
2 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 learn more
3 Total Acid Number (TAN) mg KOH/g ASTM D 2896 – 98 learn more
4 “Metal Content:Wear Metal (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si) and Metal Additive (Ca, Mg, Zn)” ppm ASTM D 5185 – 09 learn more
5 Water content By Karl Fischer ppm (mg/kg) ASTM E 6304-04 learn more
6 ISO Cleanlinee Code/ NAS Class ISO 4406 learn more
2. Advanced Package Test for In-Service Oil of Industrial Air and Gas Compressor
Package Code: ADV-INDUS-COMP
Minimum liter of sample required for each sample: 1000 mL
Lead Time: 3 days
Usually Applied for: “Analyzing Lubricating Oil condition of various type industrial air and gas compressor Equipment.This package can be used for reciprocating compressor, screw compressor, centrifugal compressor as well as axial compressor.”
Price Per-sample: Contact us
Recommended Sampling Frequency: Every 1 – 3 months
No. Parameter Unit Method Other link
1 Color ASTM D 1500 learn more
2 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 learn more
3 Total Acid Number (TAN) mg KOH/g ASTM D 2896 – 98 learn more
4 “Metal Content:Wear Metal (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si) and Metal Additive (Ca, Mg, Zn, P)” ppm ASTM D 5185 – 09 learn more
5 Water content By Karl Fischer ppm (mg/kg) ASTM E 6304-04 learn more
6 ISO Cleanlinee Code/ NAS Class ISO 4406 learn more
8 Oxidation FTIR Abs ASTM E 2412 – 04 learn more
9 Flash Point – COC °C ASTM D 92 learn more
3. Advanced Package Test for In-Service Oil of Gearbox
Package Code: ADV-INDUS-GEAR
Minimum liter of sample required for each sample: 1000 mL
Lead Time: 7 days
Usually Applied for: Analyzing Lubricating Oil condition of various type of gearboxes. Espescially reduction gearboxes which having dedicated lube oil console system
Price Per-sample: Contact us
Recommended Sampling Frequency: Every 1 – 3 months
No. Parameter Unit Method Other link
1 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 learn more
2 Total Acid Number (TAN) mg KOH/g ASTM D 2896 – 98 learn more
3 “Metal Content:Wear Metal (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si) and Metal Additive (Ca, Mg, Zn, P)” ppm ASTM D 5185 – 09 learn more
4 Water content By Karl Fischer ppm (mg/kg) ASTM E 6304-04 learn more
6 Oxidation Abs ASTM E 2412 – 04 learn more
7 Patch Test Analysis Photograph Photograph learn more
8 PQ Index Index PQ Instrument learn more
4. Advanced Package Test for In-Service Oil of Engine
Package Code: ADV-INDUS-ENGINE
Minimum liter of sample required for each sample: 1000 mL
Lead Time: 7 days
Usually Applied for: Analyzing engine oil condition, which are for Heavy Duty Mining Equipment, Fleet Transport, Marine Engine, as well as Electric Generator Engine.
Price Per-sample: Contact us
Recommended Sampling Frequency: Every 1 – 3 months
No. Parameter Unit Method Other link
1 Kinematic Viscosity at 100 °C cSt ASTM D 445 – 97 learn more
2 Total Base Number (TBN) mg KOH/g ASTM D 2896 – 98 learn more
3 “Metal Content:Wear Metal (Fe, Cu, Al, Cr, Pb, Ni, Sn, Na, Si) and Metal Additive (Ca, Mg, Zn, P)” ppm ASTM D 5185 – 09 learn more
4 FTIR (soot, Oxidation, Nitration, Water, Sox, Nox, Glycol. Fuel) Abs ASTM E 2412 – 04 learn more
5 Pentane Toluene Insoluble %wt ASTM D 893 – 02 learn more
6 Blotter Spot Test (Qualitative) Blotter Spot learn more
7 PQ Index Index PQ Instrument learn more

 

Fresh Oil

1. Regular Package Test for Fresh Lubricating Oil (GENERAL)
Package Code: FRESH-EGN-GEN
Minimum liter of sample required for each sample: 1000 mL
Lead Time: 7 days
Usually Applied for: Evaluating the fresh oil product (quality) of lubricating oil.
Price Per-sample: Contact us
Recommended Sampling Frequency: As necessary
Required Data: 1. Lubricant ID (Brand Name)
2. Batch Number (Production)
No. Parameter Unit Method Other link
1 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 Learn more
2 Kinematic Viscosity at 100 °C cSt ASTM D 445 – 97 Learn more
3 Viscosity Index ASTM D 2270 – 98 Learn more
4 Density at 15 °C kg/L ASTM D 1298-04 Learn more
5 Total Acid Number (TAN) / Total Base Number (TBN) mg KOH/g ASTM D 2896 – 98 Learn more
6 Flash Point COC °C ASTM D 92-00 Learn more
7 Pour Point °C ASTM D 97-04 Learn more
8 Appearance Visual Learn more
9 Colour ASTM D 1500 Learn more
10 Metal Additive (Ca, Mg, Zn) ppm ASTM D 5185 – 09 Learn more
11 Water Content by Distillation %wt ASTM D 95-99 Learn more
2.Regular Package Test for Fresh 2 Stroke Engine Oil
Package Code: FRESH-EGN2ST
Minimum liter of sample required for each sample: 1000 mL
Lead Time: 7 days
Usually Applied for: Evaluating the fresh oil product (quality) of lubricating oil.
Price Per-sample: Contact us
Recommended Sampling Frequency: As necessary
Required Data: 1. Lubricant ID (Brand Name)
2. Batch Number (Production)
No. Parameter Unit Method Other link
1 Color ASTM D 1500 – 98 Learn more
2 Appearance VISUAL Learn more
3 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 Learn more
4 Kinematic Viscosity at 100 °C cSt ASTM D 445 – 97 Learn more
5 Viscosity Index ASTM D 2270 – 98 Learn more
6 Density at 15 oC g/Liter ASTM D 1298 – 99 Learn more
7 Specific Gravity (SG) 60/60 ºF ASTM D 1298 – 99 Learn more
8 Total Base Number (TBN) Mg KOH / g ASTM D 2896 – 98 Learn more
9 Flash Point (COC) oC ASTM D 92 – 98a Learn more
10 Pour Point oC ASTM D 97 – 99 Learn more
11 Metal Additive (Ca, Mg, Zn) %wt ASTM D 4628 – 97 / AAS Learn more
12 Water Content by Distillation %vol ASTM D 95 – 99 Learn more
3. Regular Package Test for Fresh 4 Stroke Engine Oil
Package Code: FRESH-EGN4ST
Minimum liter of sample required for each sample: 1000 mL
Lead Time: 7 days
Usually Applied for: Evaluating the fresh oil product o(quality) of lubricating oil.
Price Per-sample: Contact us
Recommended Sampling Frequency: As necessary
Required Data: 1. Lubricant ID (Brand Name)
2. Batch Number (Production)
No. Parameter Unit Method Other link
1 Color ASTM D 1500 – 98 Learn more
2 Appearance VISUAL Learn more
3 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 Learn more
4 Kinematic Viscosity at 100 °C cSt ASTM D 445 – 97 Learn more
5 Viscosity Index ASTM D 2270 – 98 Learn more
6 Cold Cranking Simulator (CCS) – Test cP ASTM D 5293 – 99 Learn more
7 Density at 15 oC g/Liter ASTM D 1298 – 99 Learn more
8 Specific Gravity (SG) 60/60 ºF ASTM D 1298 – 99 Learn more
9 Total Base Number (TBN) Mg KOH / g ASTM D 2896 – 98 Learn more
10 Flash Point (COC) oC ASTM D 92 – 98a Learn more
11 Pour Point oC ASTM D 97 – 99 Learn more
12 Metal Additive (Mg, Zn, Ca, P, Mo) %wt ASTM D 4628 – 97 / AAS Learn more
13 Phosporus Content (P) ppm ASTM D 4047 – 00 Learn more
14 Water Content by Distillation %vol ASTM D 95 – 99 Learn more
15 Foam Tendency – Test %vol ASTM D 892 – 99 Learn more
4. Regular Package Test for New Engine Oil following SNI 06-7069
Package Code: FRESH-EGN-SNI06-7069
Minimum liter of sample required for each sample: 1000 mL
Lead Time: 7 days
Usually Applied for: Evaluating the fresh oil product o(quality) of lubricating oil.
Price Per-sample: Contact us
Recommended Sampling Frequency: As necessary
Required Data: 1. Lubricant ID (Brand Name)
2. Batch Number (Production)
No. Parameter Unit Method Other link
1 Color ASTM D 1500 – 98 Learn more
2 Appearance VISUAL Learn more
3 Density at 15 oC g/Liter ASTM D 1298 – 99 Learn more
4 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 Learn more
5 Kinematic Viscosity at 100 °C cSt ASTM D 445 – 97 Learn more
6 Viscosity Index ASTM D 2270 – 98 Learn more
7 High Temperature High Shear (HTHS-Test) cP ASTM D 4683 – 04 Learn more
8 Cold Cranking Simulator (CCS-Test) cP ASTM D 5293 – 99 Learn more
9 Flash Point (COC) oC ASTM D 92 – 98a Learn more
10 Pour Point °C ASTM D 97 – 99 Learn more
11 Total Base Number (TBN) Mg KOH / g ASTM D 2896 – 98 Learn more
12 Sulfated Ash %wt ASTM D 874-00 Learn more
13 Metal Additive (Mg, Zn, Ca, P, Mo) %wt ASTM D 4628 – 97 / AAS Learn more
14 Phosporus Content (P) ppm ASTM D 4047 – 00 Learn more
15 Foaming Characteristics seq1/seq2/seq3 ASTM D 892-98 Learn more
16 High Temperature Foam Characteristic mL Tend/mL Stbl ASTM D 6082 – 01 Learn more
17 Copper Strip Corrosion ASTM D 130-04 Learn more
18 Evaporation Loss (Noack) %wt ASTM D 5800-04 Learn more
19 Shear Stability cSt CEC L -14-A-93 Learn more
20 Water Content by Distillation %vol ASTM D 95 – 99 Learn more
5. Regular Package Test for Fresh Lubricating Oil for Industrial (Non-Engine)
Package Code: FRESH-INDUS-NONEGN
Minimum liter of sample required for each sample: 1000 mL
Lead Time: 7 days
Usually Applied for: Evaluating the fresh oil product (quality) of lubricating oil.
Price Per-sample: Contact us
Recommended Sampling Frequency: As necessary
Required Data: 1. Lubricant ID (Brand Name)
2. Batch Number (Production)
No. Parameter Unit Method Other link
1 Color ASTM D 1500 – 98 Learn more
2 Appearance VISUAL Learn more
3 Kinematic Viscosity at 40 °C cSt ASTM D 445 – 97 Learn more
4 Kinematic Viscosity at 100 °C cSt ASTM D 445 – 97 Learn more
5 Viscosity Index ASTM D 2270 – 98 Learn more
6 Density at 15 oC g/Liter ASTM D 1298 – 99 Learn more
7 Specific Gravity (SG) 60/60 ºF ASTM D 1298 – 99 Learn more
8 Total Acid Number (TAN) Mg KOH / g ASTM D 974 – 98 Learn more
9 Flash Point (COC) oC ASTM D 92 – 98a Learn more
10 Pour Point oC ASTM D 97 – 99 Learn more
11 Metal Additive (Mg, Zn, Ca, P) %wt ASTM D 4628 – 97 / AAS Learn more
12 Water Content by Karl Ficher ppm Karl Fischer – Volumetric Learn more
13 Foaming Characteristics seq1/seq2/seq3 ASTM D 892-98 Learn more
14 Demulsibility (Water Separation Test) minutes ASTM D 1401 – 98 Learn more

 

Lube Mix Compatibility

1. Lube Mix Compatibility Test
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Kinematic Viscosity at 40 °C / at 100 °C cSt ASTM D 445 – 97 Learn more
2 Total Acid Number (TAN) / Total Base Number (TBN) mg KOH/g ASTM D 2896 – 98 /ASTM D 2896 – 98 Metler Toledo Learn more
3 Metal Additive (Ca, Mg, Zn, Na) ppm ASTM D 5185 – 09 Learn more
4 Foam Characteristic ml ASTM D 892 – 01 Foaming Apparatus Learn more
5 Water Separation Characteristic ml ASTM D 1401 – 98 Learn more
6 Pentane – Toluene Insoluble %wt ASTM D 893-97 Learn more

 

Heat Transfer Oil

1. Heat Transfer Oil (HTO Package A)
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Kinematic Viscosity at 40 °C cSt ASTM D 445-04 Learn more
2 Total Acid Number (TAN) mg KOH/g ASTM D 974-97 Learn more
3 Flash Point (COC) oC ASTM D 92-00 Learn more
4 Water Content by Distilation % Vol ASTM D 95-99 Learn more
5 Density at 15 oC kg / L ASTM D 1298-00 Learn more
6 Pentane Insoluble %wt ASTM D 893 – 97 Learn more
2. Heat Transfer Oil (HTO Package B)
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Kinematic Viscosity at 40 °C cSt ASTM D 445-04 Learn more
2 Total Acid Number (TAN) mg KOH/g ASTM D 974-97 Learn more
3 Flash Point (COC) oC ASTM D 92-00 Learn more
4 Water Content by Distillation % Vol ASTM D 95-99 Learn more
5 Density at 15 oC kg / L ASTM D 1298-00 Learn more
6 Estimated Cp (Heat Transfer Coef.) Calculation Learn more
7 Iodine Number % (g-I/100mg) AOCS Cb 1-25 Learn more
8 Pentane Insoluble %wt ASTM D 893 – 97 Learn more

 

Metal Working Fluid

1. Metal Working Fluid (MWF)
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 % Brix (Refractometer Index) % Refractometer Learn more
2 pH or pHe Learn more
3 Alkalinity Total ppm SNI 06-2420-1991 Learn more
4 Hardness Total ppm Spechtofotometry Learn more
5 Chlorine Total ppm Spechtofotometry Learn more
6 Metal Content (Fe, Al, Cu, Cr, Ca, Mg) ppm ASTM D 5185 – 09 Learn more
7 Total Dissolve Solid (TDS) SNI 06-6989.3-2004 Learn more
8 Total Suspension Solid (TSS) ppm SNI 06-2413-1991 Learn more
9 Steel Corrosion Test (p=1 atm, T=20 oC, RH=60%) Pass/Not Pass Learn more

 

Solar (HSD,Dieel Fuel,Distilate Fuel D2,MGO)

1. Solar Idustrial Package
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Appearance Visual Learn more
2 Density at 15 oC kg/L ASTM D 1298-99 Learn more
3 API Gravity at 60 oF ASTM D 1298-99 Learn more
4 Kinematic Viscosity at 40 °C cSt ASTM D 445-97 Learn more
5 Flash Point (PMCC) oC ASTM D 93-98a Learn more
6 Water Content by Distillation %wt ASTM D 95-99 Learn more
7 Cetane Index ASTM D 4737-96a Learn more
8 Color ASTM D 1500-98 Learn more
9 Distillation Recovery Basis oC ASTM D 86-00a Learn more
2.Solar 48 DIRJEN Migas
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Cetane Index ASTM D 4737-96a Learn more
2 Density at 15 oC kg/L ASTM D 1298-99 Learn more
3 Kinematic Viscosity at 40 °C cSt ASTM D 445-97 Learn more
4 Sulphur Content ppm ASTM D 2622-04 Learn more
5 Distillation Characteristic oC ASTM D 86-00a Learn more
6 Flash Point (PMCC) oC ASTM D 93-00 Learn more
7 Pour Point oC ASTM D 97-96a Learn more
8 Conradson Carbon Residue on 10% residue %wt ASTM D 189-97 Learn more
9 Water Content by Distillation %vol ASTM D 95-99 Learn more
10 Copper Strip Corrosion ASTM D 130-94 Learn more
11 Ash Content %wt ASTM D 874-00 Learn more
12 Sediment ppm ASTM D 473 – 95 Learn more
13 Total Acid Number mg KOH/g ASTM D 974 Learn more
14 Appearance Organoleptic Learn more
15 Color ASTM D 1500 Learn more
3. Solar 51 DIRJEN Migas
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Cetane Index ASTM D 4737-96a Learn more
2 Density at 15 oC kg/L ASTM D 1298-99 Learn more
3 API Gravity at 60 °F ASTM D 1298-99 Learn more
4 Kinematic Viscosity at 40 °C cSt ASTM D 445-97 Learn more
5 Sulphur Content %wt ASTM D 2622-98 Learn more
6 Distillation Characteristic oC ASTM D 86-00a Learn more
7 Flash Point (PMCC) oC ASTM D 93-00 Learn more
8 Cloud Point oC ASTM D 2500-99 Learn more
9 Pour Point oC ASTM D 97-96a Learn more
10 Conradson Carbon Residue on 10% residue %wt ASTM D 189-97 Learn more
11 Water Content %vol ASTM D 95-99 Learn more
12 Copper Strip Corrosion ASTM D 130-94 Learn more
13 Ash Content %wt ASTM D 874-00 Learn more
14 Sediment % (m/m) ASTM D 473 – 95 Learn more
15 Strong Acid Number mg KOH/g ASTM D 974 Learn more
16 Total Acid Number mg KOH/g ASTM D 974 Learn more
17 Particulate mg / L ASTM D 2276 Learn more
18 Appearance Organoleptic Learn more
19 Color ASTM D 1500 Learn more
20 ISO Cleanliness Code ISO 4406 Learn more
4. HSD FUEL (ASTM D 975 – 04)
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Flash Point (PMCC) oC ASTM D 93-00 Learn more
2 Water and Sediment %vol ASTM D 1796-00 Learn more
3 Distillation Characteristic oC ASTM D 86-00a Learn more
4 Kinematic Viscosity at 40 °C cSt ASTM D 445-97 Learn more
5 Ash Content %wt ASTM D 874-00 Learn more
6 Sulphur Content %wt ASTM D 2622-98 Learn more
7 Copper Strip Corrosion ASTM D 130-94 Learn more
8 Cetane Number MU/P-J/R&D/006/VIII/08 Learn more
9 Cetane Index ASTM D 4737-03 Learn more
10 Aromatic Content %vol Gas Chromatography Learn more
11 Cloud Point ASTM D 2500-02 Learn more
12 Pour Point oC ASTM D 97-96a Learn more
13 Conradson Carbon Residue on 10% residue %wt ASTM D 189-97 Learn more
14 Lubricity on Fuel by HFRR micron ASTM D 6079-04 Learn more
15 Density at 15 oC kg/L ASTM D 1298-99 Learn more
16 Water Content %vol ASTM D 95-99 Learn more
17 Sediment % (m/m) ASTM D 473 – 95 Learn more
18 Total Acid Number mg KOH/g ASTM D 974 Learn more
19 Appearance Organoleptic Learn more
20 Color ASTM D 1500 Learn more
5. HSD Fuel (WWFC 2013)
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Cetane Number MU/P-J/R&D/006/VIII/08 Learn more
2 Cetane Index ASTM D 4737-03 Learn more
3 Density at 15 oC kg/L ASTM D 1298-99 Learn more
4 Kinematic Viscosity at 40 °C cSt ASTM D 445-97 Learn more
5 Sulphur Content %wt ASTM D 2622-98 Learn more
6 Metal Content (Zn, Cu, Mn, Ca, Na) ppm AAS Learn more
7 Aromatic Content %vol Gas Chromatography Learn more
8 Distillation Characteristic (T90 and T95) oC ASTM D 86-00a Learn more
9 Flash Point PMCC oC ASTM D 93-00 Learn more
10 Cloud Point ASTM D 2500-02 Learn more
11 Pour Point oC ASTM D 97-96a Learn more
12 Conradson Carbon Residue on 10% residue %wt ASTM D 189-97 Learn more
13 Water Content %vol ASTM D 95-99 Learn more
14 Total Acid Number mg KOH/g ASTM D 974 Learn more
15 Copper Strip Corrosion ASTM D 130-94 Learn more
16 Ash Content %wt ASTM D 874-00 Learn more
17 Particulate Total mg / L ASTM D 2276-00 Learn more
18 ISO Cleanliness Code/NAS Class ISO 4406-99 Learn more
19 Appearance Organoleptic Learn more
20 Lubricity on Fuel by HFRR micron ASTM D 6079-04 Learn more

 

Minyak Bakar (MFO, Residue Fuel Oil, Bunker C,Heavy Fuel Oil)

1. MFO – Normal Package
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Specific Gravity 60/60 oF kg/L ASTM D 1298-99 Learn more
2 Water Content by Distillation %vol ASTM D 95-99 Learn more
3 Sulphur Content ppm (mg/kg) ASTM D 2622-03 Learn more
4 Flash Point (PMCC) oC ASTM D 93-00 Learn more
5 Gross Heat Calorie Value kJ/kg ASTM D 240-97 Learn more
6 Net Heat Calorie Value kJ/kg ASTM D 240-97 Learn more
2. MFO SK Dirjen Migas 2008
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Density at 15 0C Kg/L ASTM D 1298-99 Learn more
2 Kinematic Viscosity at 50 °C cSt ASTM D 445–97 Learn more
3 Sulphur Content ppm ASTM D 1551–97 Learn more
4 Pour Point 0C ASTM D 97–04 Learn more
5 Flash Point PMCC 0C ASTM D 93–00 Learn more
6 Conradson Carbon Residue (CCR) %wt ASTM D 189-97 Learn more
7 Ash Content %wt ASTM D 482-03 Learn more
8 Sediment Content %wt ASTM D 473-02 Learn more
9 Water Content by Distillation %vol ASTM D 95-99 Learn more
10 Vanadium Content ppm ASTM D 5189-09 Learn more
11 Alumunium + Silicon Content ppm ASTM D 5185-09 Learn more

 

Minyak Diesel (IDO, MDF, MSD)

1. MDF – Normal Package
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Specific Gravity 60/60 oF kg/L ASTM D 1298-99 Learn more
2 Water Content by Distillation %vol ASTM D 95-99 Learn more
3 Viscosity Redwood I/100 oF (Convert) cSt ASTM D 445-97 Learn more
4 Flash Point PMCC oC ASTM D 93-00 Learn more
2. MDF Full Package SK Dirjen Migas
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Specific Gravity 60/60 oF kg/L ASTM D 1298-99 Learn more
2 Water Content by Distillation %vol ASTM D 95-99 Learn more
3 Viscosity Redwood I/100 oF (Convert) cSt ASTM D 445-00 Learn more
4 Sulphur Content ppm ASTM D 1551-97 Learn more
5 Conradson Carbon Residue (CCR) %wt ASTM D 189-97 Learn more
6 Sediment Content %wt ASTM D 473-02 Learn more
7 Ash Content %wt ASTM D 482-03 Learn more
8 Flash Point PMCC oC ASTM D 93-00 Learn more
9 Strong Acid Number (SAN) Learn more
10 Color ASTM D 1500-98 Learn more

 

Break Fluid

1. Brake Fluid Package (SNI 06-2769-92)
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 ERBP oC SNI 06 – 2769 – 92 Learn more
2 Wet ERBP oC SNI 06 – 2769 – 92 Learn more
3 Kinematic Viscosity at 40 °C cSt SNI 06 – 2769 – 92 Learn more
4 Kinematic Viscosity at 100 °C cSt SNI 06 – 2769 – 92 Learn more
5 Water Content by Distillation % Vol SNI 06 – 2769 – 92 Learn more
6 Density at 20 oC g/cm3 SNI 06 – 2769 – 92 Learn more
7 High Temperature Stability oC SNI 06 – 2769 – 92 Learn more
8 pH SNI 06 – 2769 – 92 Learn more

 

Grease

1. Grease Test Package A
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 NLGI Number ASTM D 217-97 Learn more
2 Type of Soap ASTM D 4628-97 / AAS Learn more
3 Penetration at 77 oF (25 oC), Worked mm ASTM D 217-97 Learn more
4 Dropping Point oC ASTM D 566-97 Learn more
2. Grease Test Package B
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 NLGI Number ASTM D 217-97 Learn more
2 Type of Soap ASTM D 4628-97 / AAS Learn more
3 Penetration at 77 oF (25 oC), Worked mm ASTM D 217-97 Learn more
4 Dropping Point oC ASTM D 566-97 Learn more
5 Base Oil Viscosity on Grease cSt ASTM D 445 (ASTM D 128) Learn more

 

Cooling Water

1. Cooling Water Analysis
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 pH SNI 06-6989.11-2004 Learn more
2 Initial Boiling Point (IBP) °C ASTM D 86-00 Learn more
3 Chlorine Total ppm SNI 06-6989.11-2004 Learn more
4 Alkalinity Total ppm SNI 06-2420-1991 Learn more
5 Hardness Total ppm SNI 06-4161-1996 Learn more
6 Metal Content (Al, Fe, Cu, Ca, Mg, Zn) ppm AAS Learn more
7 Total Dissolve Solid (TDS) ppm SNI 06-6989.27-2004 Learn more
8 Total Suspension Solid (TSS) ppm SNI 06-6989.3-2004 Learn more
9 Nitrite as Anti Rust ppm Spechtrophotometer Learn more
10 Sulphide as Anti Rust ppm Spechtrophotometer Learn more
11 Kekeruhan NTU SNI 06-2413-1991 Learn more

 

Biodiesel

1. Biodiesel Package
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Density at 40 oC kg/L ASTM D 1298-04 Learn more
2 Kinematic Viscosity at 40 °C cSt ASTM D 445-04 Learn more
3 Cetane Number MU/P-J/R&D/006/VIII/08 Learn more
4 Flash Point (PMCC) oC ASTM D 93-00 Learn more
5 Cloud Point oC ASTM D 2500-02 Learn more
6 Pour Point oC ASTM D 97-04 Learn more
7 Copper-Strip Corrosion (3 hours at 50oC) ASTM D 130-04 Learn more
8 Conradson Carbon Residue on 100% sample % (m/m) ASTM D 189-97 Learn more
9 Conradson Carbon Residue on 10% residue % (m/m) ASTM D 189-97 Learn more
10 Water and Sediment % wt ASTM D 1796-00 Learn more
11 Distillation Temperature at 90% volume oC ASTM D 86-00a Learn more
12 Sulfate Ash % (m/m) ASTM D 874-00 Learn more
13 Sulphur Content ppm (mg/kg) ASTM D 2622-03 Learn more
14 Phosphor Content ppm (mg/kg) ASTM D 4927-02 Learn more
15 TAN mg KOH/g AOCS Cd 3d-63 Learn more
16 Free-Glycerin % (m/m) AOCS Ca 14-56 Learn more
17 Total-Glycerin % (m/m) AOCS Ca 14-56 Learn more
18 Ester-Alkyl Content % (m/m) FBI A 03-03 Learn more
19 Iodium Number % (g-I2/100g) AOCS Cb 1-25 Learn more
20 Halpen test AOCS Cb 1-25 Learn more
21 Low Heating Value (LHV) & High Heating Value (HHV) kJ / kg ASTM D 240-97 Learn more

 

Gasoline

1. Gasoline Fuel
Package Code:
Minimum liter of sample required for each sample:
Lead Time:
Usually Applied for:
Price Per-sample: Contact us
Recommended Sampling Frequency:
No. Parameter Unit Method Other link
1 Appearance Visual Learn more
2 Odour Organoleptic Learn more
3 Color ASTM D 1500-98 Learn more
4 Density at 15 °C kg / L ASTM D 1298-99 Learn more
5 Research Octane Number (RON) Value IKA/P-J/R&D/002/VI/08 Learn more
6 Lead Content (Pb) ppm ASTM D 3237-02 Learn more
7 Sulphur Content ppm ASTM D 2622-03 Learn more
8 Gum Test (Unwashed) mg/100 mL ASTM D 381-03 Learn more
9 Copper Strip Corrosion Test Value ASTM D 130-04 Learn more
10 Low and High Heating Value kJ/kg ASTM D 240-97 Learn more

If you are interested in this product please call the telephone number on the right to contact us

Please call ……

(62-21) 4717001, 29688694